Industrial Data Logger · Made in India

Current Data Logger

AIOTHUB Current Data Logger continuously monitors 4-20mA process loops, split-core CT motor load currents, and DC currents in real time, capturing inrush surges, overload trips, and energy consumption with precision isolation and instant excursion alerts.

₹10,499 ₹11,999 Save ₹1,500

Starting price for single-channel current data logger. Final price depends on selected CT clamp size or multi-loop input configuration.

Select Current Range
0 A → 100 A Selected range
  • Free shipping across India
  • 1-year warranty (up to 3)
  • Professional technical support
  • NABL-traceable calibration

SKU: AIOT-CDL-SC

Inputs
4–20 mA & CTs (up to 600A)
Accuracy
±0.1% FS loop / ±0.2% CT
Sampling Rate
1 s to 24 hours
Connectivity
Wi-Fi, Ethernet, 4G
Storage
50,000+ Records
Isolation
2.5 kV Galvanic
Product Overview

What is an industrial current data logger?

An industrial current data logger continuously samples and logs electrical current flow across machines, motor circuits, or instrumentation loops—capturing 4-20mA sensor signals, AC motor load amps via split-core CTs, inrush currents, and running cycles, storing every reading with a verified timestamp.

The AIOTHUB Current Logger delivers immediate overload alerts the moment motor draw spikes past mechanical limit thresholds or process loops drop to open-circuit (under 3.8mA). With local on-board buffering (50,000+ records) and 1-year battery backup, no reading is ever lost during power trips.

It provides maintenance superintendents and plant managers an audit-ready, low-cost way to detect bearing wear, prevent pump cavitation burnouts, monitor remote telemetry transmitters, and verify machine runtime hours.

Main Chiller Motor · Load Current (Amps) Logging every 1 s
Example motor load current curve showing normal load and overload detection Current trace stays within safe 12A to 24A bounds, logs to SD during a network outage, then detects a motor overload surge at 31.8A triggering an alert. 24.0 A 12.0 A Network down saved to SD, synced later Alert: 31.8 A Overload 00:0006:0012:0018:00
Safe operational load (12.0A to 24.0A) Instant SMS, email & WhatsApp overload alert Zero data loss during outages
WHY AIOTHUB

Immediate Overload Detection, Unbroken Machine Records

From motor current monitoring to process transmitter loops, the Current Data Logger keeps your assets protected and your records audit-ready.

Audit-ready motor & loop data

Tamper-evident, time-stamped electrical records built for ISO 50001 energy audits, preventive maintenance, and machinery compliance.

Real-time alerts, zero downtime

Instant SMS, email, and WhatsApp notifications when current surges, motors overload, or loop wires disconnect.

Never lose a reading

On-board storage (50,000+ records) and internal rechargeable lithium backup ensure gap-free current logs through power trips.

Works with what you already run

Modbus RTU/TCP, MQTT, and OPC-UA drop straight into your PLCs, SCADA systems, and energy management platforms.

Industrial Standard

NABL-certified current data loggers ensure accurate, reliable, and traceable 4–20 mA process loop and CT motor current monitoring across critical factory environments.

Calibration NABL Certified
CURRENT METRICS

One Logger. Complete Current Metrics.

The AIOTHUB Current Data Logger records all fundamental current signals with precision low-drift burden circuits and high galvanic isolation.

4–20 mA Process Loops

Direct isolated input for process transmitters (pressure, flow, level), machine feedback, and valve positioning loops.

Split-Core AC CT Clamps

Non-invasive snap-on current transformers (0–50A, 0–100A, 0–250A) for motor and pump load tracking without wire cutting.

0–5A Panel CT Secondary

Direct connection to existing switchgear CT secondaries for MCC incomer current, breaker loading, and feeder monitoring.

DC Shunt & Motor Current

External Hall-effect current transducers and precision DC shunt inputs for DC drives, battery discharge, and electroplating.

TECHNICAL SPECIFICATIONS

Technical specifications

Full hardware details for electrical engineers, maintenance supervisors, and automation teams.

Current data logger specifications: Device features, sensors & communication details
Device Features
Display 1.3-Inch OLED display (128×64 resolution)
Channels 1 Isolated Channel (Optional Dual-Channel available)
Connectivity Wi-Fi, Ethernet, 4G LTE
Local Storage 50,000+ Records (On-board flash + SD card support)
Battery Type Lithium-ion Rechargeable
Backup Duration Up to 1 Year (at a 5-minute sampling interval)
Real-time Alerts SMS, Email, WhatsApp, Local Buzzer
Recording Interval 1 sec to 24 hours (configurable, time-stamped records)
Cloud Data Retention 105,120 sensor data points (up to 1 year)
Real-time Clock Accuracy up to ±3.5 ppm over −40°C to +85°C
Supported Current Inputs & Range
Process Current Loop 4–20 mA, 0–20 mA (16-bit ADC resolution)
Panel CT Secondary 0–5 A AC True RMS
Split-Core CTs 0–50 A, 0–100 A, 0–250 A, 0–600 A AC True RMS
Burden Resistor Internal precision low-drift (< 10 ppm/°C) burden circuit
Accuracy & Isolation ±0.1% FS on 4-20mA, ±0.2% FS True RMS on CTs, 2.5 kV RMS Isolation
Calibration NABL-traceable electrical calibration certificate available
Communication Interfaces
Data Communication MQTT / HTTP / HTTPS / TCP
Wi-Fi 2.4 GHz 802.11 b/g/n
Cellular GSM / 4G LTE
RS485 Industrial Isolated RS485 Interface
Protocol Modbus RTU, Modbus TCP
REST API Supported for SCADA / ERP Integration
Cloud Connectivity AIOTHUB Cloud Monitoring Platform
Data Synchronization Automatic zero-loss synchronization on reconnect
Current data logger specifications: Mechanical, logging, cloud & power details
Mechanical & Enclosure
Enclosure Type Wall Mounting / DIN-Rail Clip
Enclosure Material Flame-Retardant ABS
Dimensions 10.8 cm × 15.5 cm × 5.1 cm (L × W × H)
Protection Rating IP65 Weatherproof Enclosure
Terminal Type Industrial Pluggable Screw Terminals
Status LEDs Power, Connectivity, Alarm
Data Logging & Storage
Data Logging Continuous / Event-driven / On-threshold
Typical Logging Interval 1 s to 24 hours
Timestamp High-accuracy RTC / NTP Synchronized
Offline Data Logging Supported (buffer auto-syncs)
Data Integrity CRC32 & SHA256 per block
Data Export CSV / Excel / PDF Audit Reports
Cloud & Software Features
Dashboard Real-time current monitoring dashboard with interactive graphs
Support Live Telemetry, Historical Trends, Overload Logs
Device Status Online / Offline Heartbeat Telemetry
Remote Configuration Supported via Web Portal
User Roles Role-Based Access Control (RBAC)
Power & Environment
Input Power 9–12 V DC (Wide 9–36V DC optional)
Loop Power Output 24 V DC auxiliary loop excitation optional
Reverse Polarity Protection Yes
Over-Current Protection Yes, self-resetting PTC fuse
Operating Temperature −20°C to +60°C
Storage Temperature −20°C to +70°C

Need a datasheet or a custom CT rating configuration? Request it from our engineering team.

EASY SETUP

From Box to Live Data in Under 10 Minutes

No software coding, no downtime. Four steps to continuous, compliant current monitoring.

1

Clamp CT or wire 4-20mA loop

Snap the split-core CT clamp over the phase cable or land 4-20mA sensor wires into isolated terminals, and power with 9–12V DC.

2

Connect to network

Connect to Wi-Fi, plug in Ethernet, or insert a 4G SIM. The device activates instantly on the cloud portal.

3

Set CT ratio & overload limits

Configure CT scaling ratio (e.g. 100:5 or 100A:333mV) and enter overcurrent alert boundaries for instant WhatsApp alerts.

4

Monitor from anywhere

Track real-time motor load curves, running hours, and download automated compliance reports from any browser.

APPLICATIONS & INDUSTRIES

Trusted Across Critical Machinery & Industrial Processes

Wherever motor reliability, mechanical jam detection, and process transmitter integrity are essential, the Current Data Logger delivers.

Industrial Motors & Pumps

Track operating current, detect mechanical overload, bearing wear, impeller jamming, and prevent stator winding burnouts.

Process Loop Transmitters

Log 4–20 mA signals from pressure transmitters, magnetic flowmeters, and radar level gauges for continuous SCADA audit trails.

MCC Switchgear & Feeders

Monitor individual motor control center (MCC) feeder loads, detect phase unbalance, and verify circuit breaker capacity.

Compressors & Chillers

Record compressor motor running cycles, identify short-cycling, and detect excessive head pressure before high-pressure cutouts trip.

Energy Audits & Demand Management

Identify machinery idling current, peak demand spikes, and quantify electricity savings achieved by variable speed drives (VFDs).

DC Systems, Drives & Plating

Measure DC currents from rectifiers, electroplating tanks, DC crane motors, and solar battery storage banks via Hall-effect CTs.

Answers

Current Data Logger FAQs

Answers to common questions electrical engineers, maintenance supervisors, and purchase teams ask about our current loggers.

A current data logger continuously measures and records electrical current over time. It gives you a time-stamped history of operating current, helping you detect machine overloads, prevent motor burnouts, verify transmitter loops, and improve energy efficiency.

It supports standard 4–20 mA and 0–20 mA loops directly. For AC motors, it connects to 0–5A panel CTs or non-invasive split-core CTs with ratings ranging from 0–50A up to 600A (and up to 1000A with Rogowski coils).

Yes. Configured with fast 1-second sampling intervals, the logger accurately captures peak motor starting inrush current, sustained mechanical overload, and sudden jam surges.

Split-core CT clamps simply snap open and close around the insulated motor lead or phase cable without disconnecting the conductor or interrupting production. The CT secondary wires connect directly into the logger's terminal block.

The logger continues recording seamlessly to onboard local storage (50,000+ records) with CRC32 integrity check. An internal rechargeable Lithium-ion battery provides up to 1 year of backup (at a 5-minute sampling interval), automatically synchronizing all buffered data to the cloud when connectivity returns.

You can set upper threshold limits (e.g. 24.0 A) and lower limits (e.g. 3.8 mA for loop fault detection). When boundaries are crossed, instant notifications are sent via SMS, email, WhatsApp, and the onboard audio buzzer.

Yes. Every record is cryptographically secured with SHA256 checksums and AES-256 encryption, ensuring compliance with preventive maintenance audits and ISO 50001 energy standards.

Yes. It supports Modbus RTU over RS485, Modbus TCP, MQTT, and REST APIs, allowing seamless integration with PLCs, SCADA, and factory energy management platforms.

Yes. The input directly logs standard 2-wire and 3-wire 4-20mA process loops from pressure, flow, level, or temperature transmitters.

Yes. Every unit can be supplied with an NABL-traceable calibration certificate verifying current accuracy across its measurement range.

Yes. By pairing the logger with a DC shunt resistor or a Hall-effect DC current transducer, you can measure high DC currents from battery banks, rectifiers, and solar systems.

The AIOTHUB single-channel Current Data Logger starts from ₹10,499 for standard 4-20mA or CT configurations. Custom CT ratings and multi-channel configurations are quoted based on specific monitoring requirements.

Get a Quote for Your Current Monitoring Deployment

Tell us about your motor load or 4-20mA monitoring application and we'll configure, calibrate, and ship a current logger ready to run — pan-India, free shipping, 1-year warranty.