Industrial Data Logger · Made in India
Current Data Logger
AIOTHUB Current Data Logger continuously monitors 4-20mA process loops, split-core CT motor load currents, and DC currents in real time, capturing inrush surges, overload trips, and energy consumption with precision isolation and instant excursion alerts.
Starting price for single-channel current data logger. Final price depends on selected CT clamp size or multi-loop input configuration.
- Free shipping across India
- 1-year warranty (up to 3)
- Professional technical support
- NABL-traceable calibration
SKU: AIOT-CDL-SC
- Inputs
- 4–20 mA & CTs (up to 600A)
- Accuracy
- ±0.1% FS loop / ±0.2% CT
- Sampling Rate
- 1 s to 24 hours
- Connectivity
- Wi-Fi, Ethernet, 4G
- Storage
- 50,000+ Records
- Isolation
- 2.5 kV Galvanic
What is an industrial current data logger?
An industrial current data logger continuously samples and logs electrical current flow across machines, motor circuits, or instrumentation loops—capturing 4-20mA sensor signals, AC motor load amps via split-core CTs, inrush currents, and running cycles, storing every reading with a verified timestamp.
The AIOTHUB Current Logger delivers immediate overload alerts the moment motor draw spikes past mechanical limit thresholds or process loops drop to open-circuit (under 3.8mA). With local on-board buffering (50,000+ records) and 1-year battery backup, no reading is ever lost during power trips.
It provides maintenance superintendents and plant managers an audit-ready, low-cost way to detect bearing wear, prevent pump cavitation burnouts, monitor remote telemetry transmitters, and verify machine runtime hours.
Immediate Overload Detection, Unbroken Machine Records
From motor current monitoring to process transmitter loops, the Current Data Logger keeps your assets protected and your records audit-ready.
Audit-ready motor & loop data
Tamper-evident, time-stamped electrical records built for ISO 50001 energy audits, preventive maintenance, and machinery compliance.
Real-time alerts, zero downtime
Instant SMS, email, and WhatsApp notifications when current surges, motors overload, or loop wires disconnect.
Never lose a reading
On-board storage (50,000+ records) and internal rechargeable lithium backup ensure gap-free current logs through power trips.
Works with what you already run
Modbus RTU/TCP, MQTT, and OPC-UA drop straight into your PLCs, SCADA systems, and energy management platforms.
One Logger. Complete Current Metrics.
The AIOTHUB Current Data Logger records all fundamental current signals with precision low-drift burden circuits and high galvanic isolation.
4–20 mA Process Loops
Direct isolated input for process transmitters (pressure, flow, level), machine feedback, and valve positioning loops.
Split-Core AC CT Clamps
Non-invasive snap-on current transformers (0–50A, 0–100A, 0–250A) for motor and pump load tracking without wire cutting.
0–5A Panel CT Secondary
Direct connection to existing switchgear CT secondaries for MCC incomer current, breaker loading, and feeder monitoring.
DC Shunt & Motor Current
External Hall-effect current transducers and precision DC shunt inputs for DC drives, battery discharge, and electroplating.
Technical specifications
Full hardware details for electrical engineers, maintenance supervisors, and automation teams.
| Device Features | |
|---|---|
| Display | 1.3-Inch OLED display (128×64 resolution) |
| Channels | 1 Isolated Channel (Optional Dual-Channel available) |
| Connectivity | Wi-Fi, Ethernet, 4G LTE |
| Local Storage | 50,000+ Records (On-board flash + SD card support) |
| Battery Type | Lithium-ion Rechargeable |
| Backup Duration | Up to 1 Year (at a 5-minute sampling interval) |
| Real-time Alerts | SMS, Email, WhatsApp, Local Buzzer |
| Recording Interval | 1 sec to 24 hours (configurable, time-stamped records) |
| Cloud Data Retention | 105,120 sensor data points (up to 1 year) |
| Real-time Clock | Accuracy up to ±3.5 ppm over −40°C to +85°C |
| Supported Current Inputs & Range | |
| Process Current Loop | 4–20 mA, 0–20 mA (16-bit ADC resolution) |
| Panel CT Secondary | 0–5 A AC True RMS |
| Split-Core CTs | 0–50 A, 0–100 A, 0–250 A, 0–600 A AC True RMS |
| Burden Resistor | Internal precision low-drift (< 10 ppm/°C) burden circuit |
| Accuracy & Isolation | ±0.1% FS on 4-20mA, ±0.2% FS True RMS on CTs, 2.5 kV RMS Isolation |
| Calibration | NABL-traceable electrical calibration certificate available |
| Communication Interfaces | |
| Data Communication | MQTT / HTTP / HTTPS / TCP |
| Wi-Fi | 2.4 GHz 802.11 b/g/n |
| Cellular | GSM / 4G LTE |
| RS485 | Industrial Isolated RS485 Interface |
| Protocol | Modbus RTU, Modbus TCP |
| REST API | Supported for SCADA / ERP Integration |
| Cloud Connectivity | AIOTHUB Cloud Monitoring Platform |
| Data Synchronization | Automatic zero-loss synchronization on reconnect |
| Mechanical & Enclosure | |
|---|---|
| Enclosure Type | Wall Mounting / DIN-Rail Clip |
| Enclosure Material | Flame-Retardant ABS |
| Dimensions | 10.8 cm × 15.5 cm × 5.1 cm (L × W × H) |
| Protection Rating | IP65 Weatherproof Enclosure |
| Terminal Type | Industrial Pluggable Screw Terminals |
| Status LEDs | Power, Connectivity, Alarm |
| Data Logging & Storage | |
| Data Logging | Continuous / Event-driven / On-threshold |
| Typical Logging Interval | 1 s to 24 hours |
| Timestamp | High-accuracy RTC / NTP Synchronized |
| Offline Data Logging | Supported (buffer auto-syncs) |
| Data Integrity | CRC32 & SHA256 per block |
| Data Export | CSV / Excel / PDF Audit Reports |
| Cloud & Software Features | |
| Dashboard | Real-time current monitoring dashboard with interactive graphs |
| Support | Live Telemetry, Historical Trends, Overload Logs |
| Device Status | Online / Offline Heartbeat Telemetry |
| Remote Configuration | Supported via Web Portal |
| User Roles | Role-Based Access Control (RBAC) |
| Power & Environment | |
| Input Power | 9–12 V DC (Wide 9–36V DC optional) |
| Loop Power Output | 24 V DC auxiliary loop excitation optional |
| Reverse Polarity Protection | Yes |
| Over-Current Protection | Yes, self-resetting PTC fuse |
| Operating Temperature | −20°C to +60°C |
| Storage Temperature | −20°C to +70°C |
Need a datasheet or a custom CT rating configuration? Request it from our engineering team.
From Box to Live Data in Under 10 Minutes
No software coding, no downtime. Four steps to continuous, compliant current monitoring.
Clamp CT or wire 4-20mA loop
Snap the split-core CT clamp over the phase cable or land 4-20mA sensor wires into isolated terminals, and power with 9–12V DC.
Connect to network
Connect to Wi-Fi, plug in Ethernet, or insert a 4G SIM. The device activates instantly on the cloud portal.
Set CT ratio & overload limits
Configure CT scaling ratio (e.g. 100:5 or 100A:333mV) and enter overcurrent alert boundaries for instant WhatsApp alerts.
Monitor from anywhere
Track real-time motor load curves, running hours, and download automated compliance reports from any browser.
Trusted Across Critical Machinery & Industrial Processes
Wherever motor reliability, mechanical jam detection, and process transmitter integrity are essential, the Current Data Logger delivers.
Industrial Motors & Pumps
Track operating current, detect mechanical overload, bearing wear, impeller jamming, and prevent stator winding burnouts.
Process Loop Transmitters
Log 4–20 mA signals from pressure transmitters, magnetic flowmeters, and radar level gauges for continuous SCADA audit trails.
MCC Switchgear & Feeders
Monitor individual motor control center (MCC) feeder loads, detect phase unbalance, and verify circuit breaker capacity.
Compressors & Chillers
Record compressor motor running cycles, identify short-cycling, and detect excessive head pressure before high-pressure cutouts trip.
Energy Audits & Demand Management
Identify machinery idling current, peak demand spikes, and quantify electricity savings achieved by variable speed drives (VFDs).
DC Systems, Drives & Plating
Measure DC currents from rectifiers, electroplating tanks, DC crane motors, and solar battery storage banks via Hall-effect CTs.
Current Data Logger FAQs
Answers to common questions electrical engineers, maintenance supervisors, and purchase teams ask about our current loggers.
A current data logger continuously measures and records electrical current over time. It gives you a time-stamped history of operating current, helping you detect machine overloads, prevent motor burnouts, verify transmitter loops, and improve energy efficiency.
It supports standard 4–20 mA and 0–20 mA loops directly. For AC motors, it connects to 0–5A panel CTs or non-invasive split-core CTs with ratings ranging from 0–50A up to 600A (and up to 1000A with Rogowski coils).
Yes. Configured with fast 1-second sampling intervals, the logger accurately captures peak motor starting inrush current, sustained mechanical overload, and sudden jam surges.
Split-core CT clamps simply snap open and close around the insulated motor lead or phase cable without disconnecting the conductor or interrupting production. The CT secondary wires connect directly into the logger's terminal block.
The logger continues recording seamlessly to onboard local storage (50,000+ records) with CRC32 integrity check. An internal rechargeable Lithium-ion battery provides up to 1 year of backup (at a 5-minute sampling interval), automatically synchronizing all buffered data to the cloud when connectivity returns.
You can set upper threshold limits (e.g. 24.0 A) and lower limits (e.g. 3.8 mA for loop fault detection). When boundaries are crossed, instant notifications are sent via SMS, email, WhatsApp, and the onboard audio buzzer.
Yes. Every record is cryptographically secured with SHA256 checksums and AES-256 encryption, ensuring compliance with preventive maintenance audits and ISO 50001 energy standards.
Yes. It supports Modbus RTU over RS485, Modbus TCP, MQTT, and REST APIs, allowing seamless integration with PLCs, SCADA, and factory energy management platforms.
Yes. The input directly logs standard 2-wire and 3-wire 4-20mA process loops from pressure, flow, level, or temperature transmitters.
Yes. Every unit can be supplied with an NABL-traceable calibration certificate verifying current accuracy across its measurement range.
Yes. By pairing the logger with a DC shunt resistor or a Hall-effect DC current transducer, you can measure high DC currents from battery banks, rectifiers, and solar systems.
The AIOTHUB single-channel Current Data Logger starts from ₹10,499 for standard 4-20mA or CT configurations. Custom CT ratings and multi-channel configurations are quoted based on specific monitoring requirements.
Get a Quote for Your Current Monitoring Deployment
Tell us about your motor load or 4-20mA monitoring application and we'll configure, calibrate, and ship a current logger ready to run — pan-India, free shipping, 1-year warranty.