Industrial Data Logger · Made in India
Single-Channel Data Logger
AIOTHUB Single-Channel Data Logger accurately captures one critical parameter, ensuring reliable monitoring, easy installation, stable performance, real-time alerts, and secure data storage for industrial applications and compliance.
Starting price for single-channel base unit. Final price depends on selected input type and telemetry module.
- Free shipping across India
- 1-year warranty (up to 3)
- 24/7 technical support
- NABL-traceable calibration
SKU: AIOT-DL-SC-2025 · Category: Industrial Data Logger
- Channels
- 1 dedicated channel
- Sampling rate
- 1 s to 1 hour (configurable)
- Connectivity
- Wi-Fi, Ethernet, 4G LTE
- Protocols
- Modbus, MQTT, REST API
- Storage
- 4GB eMMC + SD up to 128GB
- Mounting
- DIN rail (35 mm) & Wall
What is an industrial single-channel data logger?
An industrial single-channel data logger is a dedicated, rugged electronic instrument that continuously acquires, timestamps, and archives one critical process variable with zero data loss and high accuracy.
Whether tracking a critical temperature loop, pump discharge pressure, cleanroom relative humidity, or 4-20mA motor load, the AIOTHUB single-channel logger delivers continuous edge monitoring, real-time WhatsApp/SMS alerts on excursion, and seamless local buffering during power cuts.
It integrates directly with your existing PLC, SCADA, or cloud dashboards over Modbus RTU, Modbus TCP, MQTT, and REST APIs, eliminating complex multi-point wiring when you only need one vital parameter monitored.
Immediate Anomaly Detection, Complete Process Safety
From boiler steam validation to pipe network leak checks, the Single-Channel Data Logger keeps your records complete and your team notified.
Audit-ready compliance data
Tamper-evident, time-stamped records built for boiler safety audits, pipeline integrity, and ISO quality standards.
Real-time alerts, zero downtime
Instant SMS, email, and WhatsApp notifications when pressure surges, sags, or leaks cross your safe threshold limits.
Never lose a reading
On-board memory and expandable SD buffer continuously log pressure data through power disruptions or network dropouts.
Works with what you already run
Modbus RTU/TCP, MQTT, and OPC-UA drop straight into your PLCs, SCADA systems, and industrial cloud dashboards.
One logger, configured for your parameter
Choose the dedicated configuration matched to the parameter you need to monitor.
Temperature (RTD / TC)
PT100, PT1000, and thermocouple inputs for cold rooms, freezers, ovens, autoclaves, and chemical reactors.
Humidity & Dew Point
Cleanroom-grade %RH sensing for warehouses, stability chambers, cleanrooms, and food storage.
Pressure Transducers
Gauge, vacuum, and differential pressure tracking for steam boilers, pipelines, pumps, and AHU ducts.
Voltage & 4–20mA Loops
4-20mA current loops, 0-10V signals, and current CTs for motor load profiling and energy auditing.
Technical specifications
Full hardware details for engineers, panel builders, and purchase teams.
| Processor & Memory | ||
|---|---|---|
| CPU | Dual-Core ARM Cortex-A7 @ 1.2GHz | High-efficiency embedded processing |
| RAM | 512MB DDR3 | Smooth multi-tasking and buffering |
| Storage | 4GB eMMC (Expandable via SD up to 128GB) | High-reliability flash storage |
| Input & Measurement | ||
| Digital / Analog Inputs | 1 Isolated Channel | High galvanic isolation |
| Supported Parameters | Temp, Pressure, Humidity, 4-20mA, 0-10V | Universal sensor support |
| Sampling Interval | 1 second to 24 hours (configurable) | User-defined interval |
| Alert Channels | SMS, Email, WhatsApp, Local Buzzer | Instant limit breach alarms |
| Communication Interfaces | ||
|---|---|---|
| Ethernet | 1x 10/100 Mbps RJ45 Port | Wired LAN & cloud telemetry |
| Serial Ports | 1x RS485 (Modbus RTU) | SCADA & PLC connectivity |
| USB | 1x USB 2.0 Host | Local configuration & export |
| Wireless | Wi-Fi (2.4GHz), 4G LTE (Optional) | Remote cloud dashboard |
| Protocols | Modbus RTU/TCP, MQTT, REST API | Standard industrial protocols |
| Power & Environment | ||
| Power Supply | 9-36V DC Wide Input | Industrial wide supply |
| Power Consumption | < 5W | Ultra low-power continuous run |
| Operating Temp | -10°C to 65°C | Rugged industrial tolerance |
| Dimensions & Mount | 120mm x 80mm x 30mm · DIN Rail Mountable | Standard 35mm DIN rail |
Need a datasheet or a custom configuration? Request it from our team.
From Box to Live Data in Under 10 Minutes
No integrator, no code. Four steps to continuous, compliant monitoring.
Connect your sensor
Connect your sensor (RTD, 4-20mA, 0-10V, or digital probe) to the isolated input terminal.
Configure on the dashboard
Set sampling frequency, parameter engineering units, and device name from any web browser.
Set alert thresholds
Define safe high and low threshold limits and choose who gets notified via SMS, email, or WhatsApp.
Monitor from anywhere
Track real-time telemetry curves, peak excursions, and historical trends on web and mobile dashboards.
Trusted Across Regulated and Demanding Environments
Wherever pressure control and leakage audits drive process safety, the Single-Channel Data Logger fits in.
Pipelines & Water Distribution
Leak detection, water hammer monitoring, and pump pressure checks across municipal or plant piping.
Boiler & Steam Systems
Continuous safety pressure logging to meet strict boiler safety regulations and audit standards.
HVAC & Cleanrooms
Differential pressure tracking across filters, containment zones, and positive pressure cleanrooms.
Oil & Gas Storage
Vessel head-space pressure tracking, custody transfer logging, and storage tank safety compliance.
Pneumatic & Hydraulic Machinery
Tracking system pressure and circuit health to prevent component failure, leaks, or seal blowouts.
Pharmaceutical & Chemical Process
Strict vessel pressure logs during batch reactions to guarantee chemical stability and quality control.
How to Choose the Right Single-Channel Data Logger
Six factors separate a logger that safely protects your monitored processes from one that fails during audit reviews.
Parameter & range
Ensure the logger's range matches your pressure levels (e.g. low draft pressure up to high bar/PSI for heavy hydraulic lines).
Sampling rate
For steady reservoirs, minutes work. To detect water hammer, transient spikes, or valve shock, 1-second rates are vital.
Connectivity
Decide on communication methods (Wi-Fi, 4G, Ethernet) to transmit alarms instantly via Modbus RTU/TCP or MQTT.
Storage & backup
Internal storage and SD cards prevent loss of critical safety or compliance pressure logs during network dropouts.
Compliance
Essential for steam boiler safety audits, pipe leak certification, HVAC air-flow audits, and hydraulic standard tracking.
Power & environment
Select robust IP65 enclosures with wide 9-36V DC surge protection to handle harsh or vibrating process floors.
Single-Channel vs Multi-Channel Data Logger
A side-by-side feature comparison to help you choose the right architecture for your deployment.
| Feature | Single-Channel | Multi-Channel |
|---|---|---|
| Parameters monitored | 1 dedicated channel | Up to 8 channels |
| Best for | One critical variable per point | Multi-point or multi-sensor sites |
| Starting price | ₹8,499 | Contact for quote |
| Real-time alerts | Included (SMS/Email/WhatsApp) | Included (SMS/Email/WhatsApp) |
| Cloud dashboard | Included | Included |
| Local SD storage | Yes (up to 128 GB) | Yes (up to 128 GB) |
| Protocols (Modbus / MQTT / OPC-UA) | Yes | Yes |
Single-Channel Data Logger FAQs
Answers to common questions about installation, parameters, compliance, and warranty.
A single-channel data logger is a device that accurately records one critical parameter such as temperature, humidity, pressure, or voltage at set intervals and stores it for monitoring and compliance. The AIOTHUB single-channel data logger is built for reliable, dedicated monitoring of one measurement point with real-time alerts and secure data storage.
You can configure it as a temperature, humidity, voltage & current, environmental, and pressure logger. This means one device platform covers many single-point monitoring needs; you just choose the parameter that matters for your site.
The AIOTHUB single-channel data logger starts from ₹8,499, making it a cost-effective choice when you need to monitor one variable per location. Pricing depends on the sensor type you choose, and every unit ships with pan-India delivery, a 1-year warranty, and 24/7 support.
Choose a single-channel logger when you have one critical variable to monitor at a point, like a single cold room, tank, or machine. It's the lower-cost, dedicated option. If you need to track up to 8 parameters or sensors from one location, the multi-channel data logger is the better fit.
Yes. It's built for factories, utilities, and regulated environments, with a rugged design, DIN-rail mounting, and a wide 9-36V DC power input. One of our pharmaceutical customers has run it continuously for months without issues, which reflects its industrial-grade reliability.
Logging intervals are configurable from once per second up to hourly, letting you balance resolution against storage and battery life for your specific process.
Yes. It supports Wi-Fi, Ethernet, and optional 4G/LTE, so you can view live readings and historical trends remotely from web or mobile. This makes it a true IoT single-channel logger for remote sites and unmanned locations.
Yes. You can set high and low thresholds for your parameter and receive instant alerts by SMS, email, and WhatsApp the moment a reading goes out of range. So a single monitored point never becomes a costly surprise.
It's designed for high-accuracy, long-term monitoring, with sensor accuracy depending on the parameter you select (for example, high-precision temperature and humidity sensing). Each unit can also be supplied with an NABL-traceable calibration certificate to keep your records audit-ready.
Very easy. No integrator and no coding needed. You wire the single sensor, power the unit with 9-36V DC, and set the sampling rate, units, and alert thresholds from any web browser. Most users are viewing live data within about 10 minutes.
Yes. It has internal storage plus an SD card slot for local buffering, so readings keep recording during network outages. When connectivity returns, the stored data syncs automatically with no gaps in the record.
Yes. It's well suited to pharma, cold chain, and cleanroom single-point monitoring, and when paired with our cloud software, it supports tamper-evident, time-stamped records for GxP and 21 CFR Part 11 compliance.
Yes. Each unit can be supplied with an NABL-traceable calibration certificate, and we offer scheduled re-calibration so your records stay audit-ready year after year.
Yes. Data can be exported to CSV/Excel for reporting, or streamed live to your platform over MQTT, Modbus TCP, or REST API. So it drops straight into existing dashboards and SCADA systems.
Readings are buffered to on-board memory and an expandable SD card (up to 128GB), giving weeks of local storage. When connectivity returns, buffered data uploads automatically with no gaps in the record.
Yes. Every unit comes with a standard 1-year hardware warranty (extendable up to 3 years), 24/7 support, and shipping across India. You can request a quote or get configuration help through our contact page or directly on WhatsApp.
Get a Quote for Your Exact Parameter and Site
Tell us about your application and we'll configure, calibrate, and ship a single-channel logger ready to run — pan-India, free shipping, 1-year warranty.



