AIOTHUB Voltage and Current Data Logger monitors electrical parameters in real time, capturing voltage sags, motor load currents (4-20mA / CTs), power factor, and energy consumption with precision isolation and instant overload alerts.

₹18,000 ₹20,500 Save ₹2,500

Starting price for single-channel analog electrical logger. Final price depends on selected CT or high-voltage probe.

Select Electrical Input Type
  • Free shipping across India
  • 1-year warranty (up to 3)
  • 24/7 technical support
  • NABL-traceable calibration

SKU: AIOT-VDL-SC-2025 · Category: Industrial Data Logger

Channels
1 isolated channel
Accuracy
±0.2% FS True RMS
Sampling rate
1 s to 1 hour (Fast Log)
Connectivity
Wi-Fi, Ethernet, 4G
Isolation
2.5 kV RMS Galvanic
Mounting
DIN rail & Panel
Product Overview

What is an industrial voltage and current data logger?

An industrial voltage and current data logger continuously measures electrical parameters like AC/DC voltage, 4-20mA loop signals, CT load currents, and calculated active power (kW/kWh), storing every reading with a verified timestamp.

The AIOTHUB logger adds what plant electrical teams need on top: real-time alerts the moment currents spike or voltage sags beyond safe bounds, local SD buffering that records through network outages, and Modbus/MQTT for immediate SCADA and ISO 50001 energy monitoring integration.

It provides an audit-ready, low-cost way to detect motor overloads, balance phases, monitor process transmitters, and cut peak demand penalties.

Main Chiller Motor · Load Current (Amps) Logging every 1 s
Example motor load current curve showing normal load and overload detection Current trace stays within safe 12A to 24A bounds, logs to SD during a network outage, then detects a motor overload surge at 31.8A triggering an alert. 24.0 A 12.0 A Network down saved to SD, synced later Alert: 31.8 A Overload 00:0006:0012:0018:00
Safe operational load (12.0A to 24.0A) SMS, email & WhatsApp overload alert No gaps during outages
WHY AIOTHUB

Immediate Overload Detection, Complete Electrical Safety

From motor current monitoring to plant energy audits, the Voltage & Current Data Logger keeps your records complete and your team notified.

Audit-ready compliance data

Tamper-evident, time-stamped electrical records built for ISO 50001 energy audits, power quality validation, and safety standards.

Real-time alerts, zero downtime

Instant SMS, email, and WhatsApp notifications when current surges, voltage sags, or phase imbalances occur.

Never lose a reading

On-board flash and expandable SD buffer continuously log electrical telemetry through power disruptions or network dropouts.

Works with what you already run

Modbus RTU/TCP, MQTT, and OPC-UA drop straight into your PLCs, SCADA systems, and energy management dashboards.

Industrial Standard

NABL-certified electrical data loggers ensure accurate, reliable, and traceable voltage, current, and energy monitoring, meeting stringent manufacturing and power utility quality standards.

Calibration NABL Certified
ELECTRICAL METRICS

One Logger. Complete Electrical Metrics.

The AIOTHUB Voltage & Current Data Logger records all fundamental electrical signals with high galvanic isolation.

4–20 mA Current Loops

Direct isolated input for process transmitters (pressure, flow, level), machine feedback, and valve positioning loops.

0–10V / ±10V Voltage

Precision analog voltage logging from sensors, PLC analog outputs, tachometers, and DC control power rails.

AC/DC Current (CTs)

Non-invasive split-core and solid-core current transformers (0–5A, 0–100A, up to 1000A) for motor load monitoring.

True RMS Power & Energy

Real-time calculation of active power (kW), total energy (kWh), peak demand, and line power factor.

TECHNICAL SPECIFICATIONS

Technical specifications

Full hardware details for electrical engineers, panel builders, and energy auditors.

Voltage and current data logger specifications, part 1
Core System
Processor 32-bit Industrial MCU Stable long-term logging
RTC ±2 ppm with battery backup Accurate timestamps
Time Sync NTP + Cellular + GPS optional CFR-compliant time integrity
Watchdog & Brownout Enabled Prevents data loss
Electrical Measurement
Sensor Type Voltage & Current Probes / Transducers Flexible sensor support
Voltage Range 0–10 V / ±10 V PLC & sensors
Current Range 0–20 mA / 4–20 mA Transmitters
Measurement Range 0–10 V / 4–20 mA Covers all analog loops
Accuracy ±0.1% of full scale Process-grade data
Resolution 24-bit ADC High accuracy
Input Impedance > 1 MΩ No signal loading
Isolation Galvanic isolation (2.5 kV RMS) Electrical noise immunity
Input
Channel Count 1 Simple & cost-effective
Input Protection Over-voltage & surge protected Safe for field wiring
Data Logging
Logging Interval 1 sec to 60 min HACCP & pharma compliant
Storage 8–32 GB Industrial SD Card 1–5 years of data
Backup Internal Flash Zero data loss
Data Format Encrypted CSV + JSON Audit & cloud ready
Checksums CRC + SHA256 Tamper detection
Data Integrity CRC + power-loss protection No corrupted files
Voltage and current data logger specifications, part 2
Alarms & Alerts
Alarm Type High / Low / Out-of-range Prevents failures
Local Alert Buzzer & LED Instant warning
Remote Alert SMS / Email / Cloud App Immediate action
Connectivity
USB USB-C Plug & download
Wifi Optional (2.4 GHz) Local monitoring
Cellular Optional 4G / NB-IoT Remote cold rooms
Cloud FDA-ready cloud Central compliance
Power
Input 9–36 V DC Industrial supply
Battery Backup 48–120 hours Power failure safety
Low-Power Mode Yes Long backup time
Security
Encryption AES-256 + TLS 1.3 Data protection
Authentication Device certificates Prevent manipulation
Secure Boot Enabled No fake firmware
Mechanical
Enclosure IP65 Industrial Dust & water resistant
Operating Temp −40°C to +85°C Freezer compatible
Mounting Wall / DIN rail Easy installation
Compliance
Industrial CE, EMC ready Certification
Pharma 21 CFR Part 11 ready Audit ready
Data Export CSV, PDF Reports & audits

Need a datasheet or a custom configuration? Request it from our team.

EASY SETUP

From Box to Live Data in Under 10 Minutes

No integrator, no code. Four steps to continuous, compliant power monitoring.

1

Wire inputs or CTs

Clamp current transformers over the target conductor or wire voltage/4-20mA leads into isolated terminals.

2

Configure on dashboard

Set CT ratio, voltage scaling (V/kV), and sampling frequency from any desktop or mobile browser.

3

Set alert thresholds

Define high/low voltage, overcurrent, and power boundaries and assign team members for SMS/WhatsApp alerts.

4

Monitor from anywhere

Track real-time load curves, peak demand trends, and download automated energy audit reports.

APPLICATIONS & INDUSTRIES

Trusted Across Regulated and Demanding Environments

Wherever electrical reliability, motor protection, and energy audits drive operational efficiency, the Voltage & Current Logger fits in.

Industrial Motors & Pumps

Track operating current, detect mechanical overload, bearing binding, and prevent stator winding burnouts.

Solar PV & Battery Storage

Measure DC string voltage, battery charge/discharge currents, and inverter efficiency in solar microgrids.

Energy Audits & ISO 50001

Log feeder consumption (kWh), identify peak demand surges, and verify energy savings across factory plant areas.

UPS & Backup Generators

Monitor transfer switch voltage, battery bank discharge curves, and generator output stability during grid outages.

Factory Substation Panels

Continuous feeder voltage monitoring, catching voltage sags, power surges, and harmonic load imbalances.

Process Loop Transmitters

Record 4-20mA and 0-10V signals from remote pressure, level, and flow transmitters for SCADA audit trails.

BUYER'S GUIDE

How to Choose the Right Voltage & Current Data Logger

Six factors separate a logger that safely protects your electrical equipment from one that fails during audit reviews.

01

Input signal compatibility

Identify whether you need 4-20mA process loop logging, 0-10V analog voltage, or non-invasive AC/DC current transformers (CTs).

02

True RMS calculation

Ensure the device calculates True RMS to accurately measure distorted or non-linear loads created by VFDs and power electronics.

03

High galvanic isolation

Verify high galvanic isolation (2.5 kV RMS) between high-voltage inputs and communication buses to prevent equipment damage.

04

Sampling speed & inrush

Fast sampling rates down to 1 second are essential to capture motor start inrush spikes and transient voltage sags.

05

Connectivity & SCADA

Select loggers supporting Modbus RTU/TCP, MQTT, and OPC-UA for drop-in integration into energy management and PLC systems.

06

Memory buffer & backup

Ensure on-board SD buffering and battery backup so plant power interruptions cause zero loss of electrical telemetry records.

PRODUCT COMPARISON

Single-Channel vs Multi-Channel Voltage & Current Data Logger

A side-by-side feature comparison to help you choose the right architecture for your deployment.

Feature Single-Channel Multi-Channel
Parameters monitored 1 dedicated Voltage / Current / 4-20mA channel Up to 8 isolated electrical channels
Best for One critical motor, feeder, or 4-20mA loop Multi-feeder panels or 3-phase load profiling
Starting price ₹18,000 Contact for quote
Real-time alerts Included (SMS/Email/WhatsApp) Included (SMS/Email/WhatsApp)
Cloud dashboard Included Included
Local SD storage Yes (8–32 GB) Yes (up to 128 GB)
Protocols (Modbus / MQTT / OPC-UA) Yes Yes
FREQUENTLY ASKED QUESTIONS

Voltage & Current Data Logger FAQs

The questions electrical engineers, plant managers, and purchase teams ask us most before ordering.

A voltage and current data logger automatically measures and records electrical parameters like AC/DC voltage, 4-20mA loop currents, and CT load currents over time. It gives you a time-stamped history of electrical performance, helping you detect fluctuations, prevent overloads, and improve energy efficiency.

It measures AC/DC voltage (0–10V, 0–500V via divider modules), 4–20 mA process loops, current via CT clamps (0–1000A), active power (kW), total energy (kWh), and line frequency.

Yes. Configured with fast sampling rates (down to 1 second), the logger captures motor starting inrush currents, short-duration voltage sags, and transient overload events.

The unit features 2.5 kV RMS galvanic isolation between input channels, power supply, and communication interfaces, preventing dangerous ground loops and protecting connected equipment.

The logger continues recording locally to an industrial SD card without missing a reading. An onboard rechargeable lithium battery sustains 48 to 120 hours of operation, auto-uploading data when connectivity returns.

You can set upper and lower threshold limits for voltage and current. When limits are exceeded, instant notifications are sent via SMS, email, WhatsApp, and the onboard audio buzzer.

Yes. Every record is cryptographically secured with SHA256 checksums and AES-256 encryption, ensuring compliance with industrial energy audits and ISO 50001 standards.

Yes. It supports Modbus RTU (RS485), Modbus TCP, MQTT, and OPC-UA, allowing seamless integration with PLCs, SCADA, and factory energy management platforms.

Yes. The analog input directly logs standard 2-wire and 3-wire 4-20mA process loops from pressure, flow, level, or temperature transmitters.

Yes. Every unit can be supplied with an NABL-traceable calibration certificate for voltage and current channels.

Yes. The logger supports DC voltage and Hall-effect DC current sensors, making it well-suited for solar PV arrays, battery storage, and DC backup systems.

The AIOTHUB single-channel Voltage & Current Data Logger starts from ₹18,000 for standard analog 4-20mA/0-10V configurations. Multi-channel and CT models are quoted based on specific monitoring requirements.

Get a Quote for Your Electrical Monitoring Deployment

Tell us about your application and we'll configure, calibrate, and ship a voltage/current logger ready to run — pan-India, free shipping, 1-year warranty.