SKU: AIOT-VDL-SC-2025 · Category: Industrial Data Logger
- Channels
- 1 isolated channel
- Accuracy
- ±0.2% FS True RMS
- Sampling rate
- 1 s to 1 hour (Fast Log)
- Connectivity
- Wi-Fi, Ethernet, 4G
- Isolation
- 2.5 kV RMS Galvanic
- Mounting
- DIN rail & Panel
What is an industrial voltage and current data logger?
An industrial voltage and current data logger continuously measures electrical parameters like AC/DC voltage, 4-20mA loop signals, CT load currents, and calculated active power (kW/kWh), storing every reading with a verified timestamp.
The AIOTHUB logger adds what plant electrical teams need on top: real-time alerts the moment currents spike or voltage sags beyond safe bounds, local SD buffering that records through network outages, and Modbus/MQTT for immediate SCADA and ISO 50001 energy monitoring integration.
It provides an audit-ready, low-cost way to detect motor overloads, balance phases, monitor process transmitters, and cut peak demand penalties.
Immediate Overload Detection, Complete Electrical Safety
From motor current monitoring to plant energy audits, the Voltage & Current Data Logger keeps your records complete and your team notified.
Audit-ready compliance data
Tamper-evident, time-stamped electrical records built for ISO 50001 energy audits, power quality validation, and safety standards.
Real-time alerts, zero downtime
Instant SMS, email, and WhatsApp notifications when current surges, voltage sags, or phase imbalances occur.
Never lose a reading
On-board flash and expandable SD buffer continuously log electrical telemetry through power disruptions or network dropouts.
Works with what you already run
Modbus RTU/TCP, MQTT, and OPC-UA drop straight into your PLCs, SCADA systems, and energy management dashboards.
One Logger. Complete Electrical Metrics.
The AIOTHUB Voltage & Current Data Logger records all fundamental electrical signals with high galvanic isolation.
4–20 mA Current Loops
Direct isolated input for process transmitters (pressure, flow, level), machine feedback, and valve positioning loops.
0–10V / ±10V Voltage
Precision analog voltage logging from sensors, PLC analog outputs, tachometers, and DC control power rails.
AC/DC Current (CTs)
Non-invasive split-core and solid-core current transformers (0–5A, 0–100A, up to 1000A) for motor load monitoring.
True RMS Power & Energy
Real-time calculation of active power (kW), total energy (kWh), peak demand, and line power factor.
Technical specifications
Full hardware details for electrical engineers, panel builders, and energy auditors.
| Core System | ||
|---|---|---|
| Processor | 32-bit Industrial MCU | Stable long-term logging |
| RTC | ±2 ppm with battery backup | Accurate timestamps |
| Time Sync | NTP + Cellular + GPS optional | CFR-compliant time integrity |
| Watchdog & Brownout | Enabled | Prevents data loss |
| Electrical Measurement | ||
| Sensor Type | Voltage & Current Probes / Transducers | Flexible sensor support |
| Voltage Range | 0–10 V / ±10 V | PLC & sensors |
| Current Range | 0–20 mA / 4–20 mA | Transmitters |
| Measurement Range | 0–10 V / 4–20 mA | Covers all analog loops |
| Accuracy | ±0.1% of full scale | Process-grade data |
| Resolution | 24-bit ADC | High accuracy |
| Input Impedance | > 1 MΩ | No signal loading |
| Isolation | Galvanic isolation (2.5 kV RMS) | Electrical noise immunity |
| Input | ||
| Channel Count | 1 | Simple & cost-effective |
| Input Protection | Over-voltage & surge protected | Safe for field wiring |
| Data Logging | ||
| Logging Interval | 1 sec to 60 min | HACCP & pharma compliant |
| Storage | 8–32 GB Industrial SD Card | 1–5 years of data |
| Backup | Internal Flash | Zero data loss |
| Data Format | Encrypted CSV + JSON | Audit & cloud ready |
| Checksums | CRC + SHA256 | Tamper detection |
| Data Integrity | CRC + power-loss protection | No corrupted files |
| Alarms & Alerts | ||
|---|---|---|
| Alarm Type | High / Low / Out-of-range | Prevents failures |
| Local Alert | Buzzer & LED | Instant warning |
| Remote Alert | SMS / Email / Cloud App | Immediate action |
| Connectivity | ||
| USB | USB-C | Plug & download |
| Wifi | Optional (2.4 GHz) | Local monitoring |
| Cellular | Optional 4G / NB-IoT | Remote cold rooms |
| Cloud | FDA-ready cloud | Central compliance |
| Power | ||
| Input | 9–36 V DC | Industrial supply |
| Battery Backup | 48–120 hours | Power failure safety |
| Low-Power Mode | Yes | Long backup time |
| Security | ||
| Encryption | AES-256 + TLS 1.3 | Data protection |
| Authentication | Device certificates | Prevent manipulation |
| Secure Boot | Enabled | No fake firmware |
| Mechanical | ||
| Enclosure | IP65 Industrial | Dust & water resistant |
| Operating Temp | −40°C to +85°C | Freezer compatible |
| Mounting | Wall / DIN rail | Easy installation |
| Compliance | ||
| Industrial | CE, EMC ready | Certification |
| Pharma | 21 CFR Part 11 ready | Audit ready |
| Data Export | CSV, PDF | Reports & audits |
Need a datasheet or a custom configuration? Request it from our team.
From Box to Live Data in Under 10 Minutes
No integrator, no code. Four steps to continuous, compliant power monitoring.
Wire inputs or CTs
Clamp current transformers over the target conductor or wire voltage/4-20mA leads into isolated terminals.
Configure on dashboard
Set CT ratio, voltage scaling (V/kV), and sampling frequency from any desktop or mobile browser.
Set alert thresholds
Define high/low voltage, overcurrent, and power boundaries and assign team members for SMS/WhatsApp alerts.
Monitor from anywhere
Track real-time load curves, peak demand trends, and download automated energy audit reports.
Trusted Across Regulated and Demanding Environments
Wherever electrical reliability, motor protection, and energy audits drive operational efficiency, the Voltage & Current Logger fits in.
Industrial Motors & Pumps
Track operating current, detect mechanical overload, bearing binding, and prevent stator winding burnouts.
Solar PV & Battery Storage
Measure DC string voltage, battery charge/discharge currents, and inverter efficiency in solar microgrids.
Energy Audits & ISO 50001
Log feeder consumption (kWh), identify peak demand surges, and verify energy savings across factory plant areas.
UPS & Backup Generators
Monitor transfer switch voltage, battery bank discharge curves, and generator output stability during grid outages.
Factory Substation Panels
Continuous feeder voltage monitoring, catching voltage sags, power surges, and harmonic load imbalances.
Process Loop Transmitters
Record 4-20mA and 0-10V signals from remote pressure, level, and flow transmitters for SCADA audit trails.
How to Choose the Right Voltage & Current Data Logger
Six factors separate a logger that safely protects your electrical equipment from one that fails during audit reviews.
Input signal compatibility
Identify whether you need 4-20mA process loop logging, 0-10V analog voltage, or non-invasive AC/DC current transformers (CTs).
True RMS calculation
Ensure the device calculates True RMS to accurately measure distorted or non-linear loads created by VFDs and power electronics.
High galvanic isolation
Verify high galvanic isolation (2.5 kV RMS) between high-voltage inputs and communication buses to prevent equipment damage.
Sampling speed & inrush
Fast sampling rates down to 1 second are essential to capture motor start inrush spikes and transient voltage sags.
Connectivity & SCADA
Select loggers supporting Modbus RTU/TCP, MQTT, and OPC-UA for drop-in integration into energy management and PLC systems.
Memory buffer & backup
Ensure on-board SD buffering and battery backup so plant power interruptions cause zero loss of electrical telemetry records.
Single-Channel vs Multi-Channel Voltage & Current Data Logger
A side-by-side feature comparison to help you choose the right architecture for your deployment.
| Feature | Single-Channel | Multi-Channel |
|---|---|---|
| Parameters monitored | 1 dedicated Voltage / Current / 4-20mA channel | Up to 8 isolated electrical channels |
| Best for | One critical motor, feeder, or 4-20mA loop | Multi-feeder panels or 3-phase load profiling |
| Starting price | ₹18,000 | Contact for quote |
| Real-time alerts | Included (SMS/Email/WhatsApp) | Included (SMS/Email/WhatsApp) |
| Cloud dashboard | Included | Included |
| Local SD storage | Yes (8–32 GB) | Yes (up to 128 GB) |
| Protocols (Modbus / MQTT / OPC-UA) | Yes | Yes |
Voltage & Current Data Logger FAQs
The questions electrical engineers, plant managers, and purchase teams ask us most before ordering.
A voltage and current data logger automatically measures and records electrical parameters like AC/DC voltage, 4-20mA loop currents, and CT load currents over time. It gives you a time-stamped history of electrical performance, helping you detect fluctuations, prevent overloads, and improve energy efficiency.
It measures AC/DC voltage (0–10V, 0–500V via divider modules), 4–20 mA process loops, current via CT clamps (0–1000A), active power (kW), total energy (kWh), and line frequency.
Yes. Configured with fast sampling rates (down to 1 second), the logger captures motor starting inrush currents, short-duration voltage sags, and transient overload events.
The unit features 2.5 kV RMS galvanic isolation between input channels, power supply, and communication interfaces, preventing dangerous ground loops and protecting connected equipment.
The logger continues recording locally to an industrial SD card without missing a reading. An onboard rechargeable lithium battery sustains 48 to 120 hours of operation, auto-uploading data when connectivity returns.
You can set upper and lower threshold limits for voltage and current. When limits are exceeded, instant notifications are sent via SMS, email, WhatsApp, and the onboard audio buzzer.
Yes. Every record is cryptographically secured with SHA256 checksums and AES-256 encryption, ensuring compliance with industrial energy audits and ISO 50001 standards.
Yes. It supports Modbus RTU (RS485), Modbus TCP, MQTT, and OPC-UA, allowing seamless integration with PLCs, SCADA, and factory energy management platforms.
Yes. The analog input directly logs standard 2-wire and 3-wire 4-20mA process loops from pressure, flow, level, or temperature transmitters.
Yes. Every unit can be supplied with an NABL-traceable calibration certificate for voltage and current channels.
Yes. The logger supports DC voltage and Hall-effect DC current sensors, making it well-suited for solar PV arrays, battery storage, and DC backup systems.
The AIOTHUB single-channel Voltage & Current Data Logger starts from ₹18,000 for standard analog 4-20mA/0-10V configurations. Multi-channel and CT models are quoted based on specific monitoring requirements.