Industrial Data Logger · Made in India

Environmental Data Logger

AIOTHUB Environmental Data Logger continuously measures ambient temperature, relative humidity, barometric pressure, CO₂, and air quality parameters across cleanrooms, warehouses, and smart buildings, providing comprehensive environmental insights that support compliance, product quality, workplace safety, and data-driven decisions.

₹20,000 ₹24,000 Save ₹4,000

Starting price for standard environmental logger. Final price depends on sensor selection (CO₂, VOCs, Barometer).

Select Environmental Parameters
  • Free shipping across India
  • 1-year warranty (up to 3)
  • 24/7 technical support
  • NABL-traceable calibration

SKU: AIOT-EDL-SC-2025 · Category: Industrial Data Logger

Multi-Sensor
Temp, %RH, Baro, CO₂
Accuracy
±0.2°C / ±1.5% RH
Sampling rate
1 s to 1 hour (Fast Log)
Connectivity
Wi-Fi, Ethernet, 4G
Storage
8–32 GB SD Memory
Enclosure
IP65 Weatherproof
Product Overview

What is an industrial environmental data logger?

An industrial environmental data logger records ambient temperature, relative humidity (%RH), atmospheric barometric pressure, CO₂, and air quality over time, storing every reading with a cryptographically verified timestamp.

The AIOTHUB logger adds what industrial cleanrooms and smart facilities need on top: real-time alerts the moment humidity, temperature, or CO₂ drift beyond safe bounds, local SD buffering that keeps logging through power cuts or network dropouts, and Modbus/MQTT for immediate BMS/PLC integration.

It provides the most reliable, tamper-evident foundation for cleanroom compliance, laboratory mapping, and energy-efficient HVAC ventilation control.

Cleanroom Zone 1 · 24-Hour Ambient Profile Logging every 1 s
Example cleanroom environmental profile showing humidity control and offline buffering Relative humidity curve stays within normal 40% to 55% RH limits, logs to SD during a network outage, then detects an excursion at 62% RH triggering an instant alert. 60% RH 35% RH Network down saved to SD, synced later Alert: 62.5% RH 00:0006:0012:0018:00
Safe operational band (40–55% RH / 21–24°C) SMS, email & WhatsApp excursion alert No gaps during outages
WHY AIOTHUB

Immediate Anomaly Detection, Complete Climate Safety

From cleanroom ISO validation to corporate IAQ monitoring, the Environmental Data Logger keeps your records complete and your team notified.

Audit-ready compliance data

Tamper-evident, time-stamped records built for cleanroom ISO 14644, FDA 21 CFR Part 11, and ASHRAE IAQ standards.

Real-time alerts, zero downtime

Instant SMS, email, and WhatsApp notifications when temperature, humidity, or CO₂ cross your safe threshold limits.

Never lose a reading

On-board flash and expandable 8–32 GB SD buffer continuously log climate data through power disruptions or network dropouts.

Works with what you already run

Modbus RTU/TCP, MQTT, and OPC-UA drop straight into your PLCs, BMS building automation, and SCADA systems.

Industrial Standard

NABL-certified environmental data loggers ensure accurate, reliable, and traceable climate monitoring, meeting stringent cleanroom, laboratory, and indoor air quality standards.

Calibration NABL Certified
ENVIRONMENTAL METRICS

One Logger. Complete Ambient Environmental Metrics.

The AIOTHUB Environmental Data Logger records all core ambient and indoor air quality parameters with multi-sensor precision.

Temperature & %RH

Polymeric humidity and bandgap temperature sensor with PTFE particulate filter for cleanrooms and stability chambers.

NDIR Optical CO₂

Non-Dispersive Infrared optical sensor with auto-baseline calibration (ABC) for demand-controlled ventilation (DCV).

Barometric Pressure

Piezo-resistive MEMS absolute pressure sensor for cleanroom room differential tracking and altitude profiling.

VOCs, PM2.5 & Lux

Optional MOx multi-gas sensor for Total VOC (TVOC), optical PM2.5 laser counter, and ambient light level (Lux).

TECHNICAL SPECIFICATIONS

Technical specifications

Full hardware details for engineers and purchase teams.

Environmental data logger specifications, part 1
Processor & Memory
CPU Dual-Core ARM Cortex-A7 @ 1.2GHz Embedded IoT processor
RAM 512MB DDR3 Multi-stream telemetry buffer
Storage 4GB eMMC (Expandable via SD up to 128GB) Reliable on-board storage
Sensors & Input
Parameters Temp, %RH, Barometric Pressure, CO₂, TVOC, Lux Comprehensive multi-parameter
Temperature range −40°C to +125°C (±0.2°C accuracy, 0.01°C res) Precision RTD / IC sensing
Humidity range 0 to 100% RH (±1.5% RH accuracy, <0.25% drift/yr) Cleanroom grade RH
Barometric range 300 to 1100 hPa (±0.5 hPa absolute, 0.01 hPa res) Pressure & altitude tracking
CO₂ Measurement NDIR 0–5000 ppm (±30 ppm + 3% of reading) Optical NDIR sensor
VOC & PM2.5 TVOC (0-60,000 ppb) & Laser PM2.5/PM10 (Optional) IAQ & cleanroom compliance
Logging interval 1 second to 24 hours (configurable) User-defined interval
Alerts SMS, email, WhatsApp, Audio Buzzer Instant threshold alarms
Environmental data logger specifications, part 2
Communication Interfaces
Ethernet 1x 10/100 Mbps RJ45 Port Wired network connectivity
Serial Ports 1x RS485 (Modbus RTU) BMS & SCADA integration
USB 1x USB 2.0 Host Local diagnostics & flash
Wireless Wi-Fi 2.4 GHz, 4G LTE optional Cloud & mobile telemetry
Protocols Modbus RTU/TCP, MQTT, REST API Standard industrial protocol
Power & Environment
Power Supply 9-36V DC Wide Input Industrial wide supply
Power Consumption < 5W Energy efficient continuous run
Battery Backup 48–120 Hours Rechargeable Li-ion backup Uninterrupted offline logging
Enclosure & Mount IP65 Wall Mount / Weatherproof Polycarbonate Cleanroom & outdoor rated
Compliance FDA 21 CFR Part 11 Ready, CE, RoHS, ISO 9001 Audit ready compliance

Need a datasheet or a custom sensor configuration? Request it from our team.

EASY SETUP

From Box to Live Data in Under 10 Minutes

No integrator, no code. Four steps to continuous, compliant climate monitoring.

1

Mount & power device

Mount the IP65 enclosure on the wall or DIN rail and connect to 9–36V DC or standard AC adapter.

2

Configure on dashboard

Set sampling interval, alarm setpoints, and room labels from any mobile or desktop web browser.

3

Set alert thresholds

Define multi-level temperature, %RH, or CO₂ limits and assign team members for SMS/WhatsApp notifications.

4

Monitor from anywhere

Track real-time ambient curves, generate automated compliance PDFs, and view long-term trends.

APPLICATIONS & INDUSTRIES

Trusted Across Regulated and Demanding Environments

Wherever environmental stability, indoor air quality, and cleanroom validation drive process safety, the Environmental Data Logger fits in.

Pharma Cleanrooms & Labs

Continuous temperature, humidity, and room pressure validation meeting ISO 14644 and 21 CFR Part 11 audit requirements.

Smart Buildings & IAQ

Monitor CO₂ and VOC levels to drive Demand-Controlled Ventilation (DCV) and achieve ASHRAE 62.1 and WELL standards.

Semiconductor & Electronics

Ensure tight humidity control to prevent electrostatic discharge (ESD) and maintain microscopic particle cleanliness.

Greenhouses & Hydroponics

Track Vapor Pressure Deficit (VPD), ambient light (Lux), and CO₂ enrichment levels to optimize crop yields.

Controlled Warehouses

Protect high-value perishables, archival documents, and sensitive chemical inventory with multi-zone mapping.

Weather & City Monitoring

Deploy weatherproof stations to collect ambient atmospheric barometric pressure, heat index, and urban IAQ datasets.

BUYER'S GUIDE

How to Choose the Right Environmental Data Logger

Six factors separate a logger that safely protects your critical environments from one that fails during audit reviews.

01

Parameter selection

Determine required parameters: basic Temp+%RH vs multi-gas suites with NDIR CO₂, barometric pressure, or VOCs.

02

Sensor precision & drift

Look for ±0.2°C temperature accuracy and long-term <0.25% RH annual drift with pre-calibrated digital sensor modules.

03

Connectivity & IoT cloud

Ensure seamless communication (Wi-Fi, 4G, Ethernet) to stream continuous telemetry via Modbus RTU/TCP or MQTT.

04

Storage & battery backup

Verify internal SD memory and 48–120 hour rechargeable lithium backup to prevent gap loss during power blackouts.

05

Regulatory compliance

Check for FDA 21 CFR Part 11 ready audit trails, NABL traceability certificates, and automated tamper-proof PDF generation.

06

Enclosure & environment

Select IP65 weatherproof enclosures with PTFE dust filters and solar radiation shields for harsh or outdoor environments.

PRODUCT COMPARISON

Single-Channel vs Multi-Channel Environmental Data Logger

A side-by-side feature comparison to help you choose the right architecture for your deployment.

Feature Single-Channel / Integrated Multi-Channel Distributed
Parameters monitored Integrated Temp, %RH, Baro, CO₂ Up to 16 external wired/wireless probes
Best for Single cleanroom, lab, or AHU duct Facility-wide mapping across multiple rooms
Starting price ₹20,000 Contact for quote
Real-time alerts Included (SMS/Email/WhatsApp) Included (SMS/Email/WhatsApp)
Cloud dashboard Included Included
Local SD storage Yes (8–32 GB) Yes (up to 128 GB)
Protocols (Modbus / MQTT / OPC-UA) Yes Yes
FREQUENTLY ASKED QUESTIONS

Environmental Data Logger FAQs

The questions engineers, cleanroom managers, and purchase teams ask us most before ordering.

An environmental data logger automatically measures and records atmospheric conditions such as temperature, relative humidity, barometric pressure, CO₂, and VOCs over time. It gives you a time-stamped history of environmental changes, helping you maintain compliance, optimize HVAC systems, and ensure workplace safety.

An environmental data logger is used to continuously monitor indoor climate conditions in pharmaceutical cleanrooms, stability chambers, hospital isolation rooms, corporate office IAQ systems, greenhouses, and warehouses. It is essential when you need live readings and audit-ready historical compliance reports.

AIOTHUB supports Ambient Temperature (−40°C to +125°C), Relative Humidity (0 to 100% RH), Atmospheric Barometric Pressure (300 to 1100 hPa), Optical CO₂ (0 to 5000 ppm), Total VOCs, Particulate Matter (PM2.5/PM10), and Ambient Light (Lux).

Yes. Equipped with dual-wavelength NDIR optical sensors, it precisely tracks CO₂ levels to optimize Demand-Controlled Ventilation (DCV) and meet ASHRAE 62.1 and WELL building standards.

Yes. The logger is widely used for cleanroom qualification under ISO 14644 and USFDA 21 CFR Part 11, delivering time-stamped electronic records, SHA256 checksums, and automated PDF audit reports.

Yes. It connects directly with building management systems (BMS) via Modbus RTU/TCP to modulate fresh air dampers, optimize chiller loading, and reduce facility energy consumption.

Yes. Built in an IP65 rated weatherproof enclosure with solar radiation shields, the logger is well-suited for agricultural greenhouses, solar farms, and outdoor microclimate weather stations.

Yes. Using 4G LTE cellular, Wi-Fi, or Ethernet, data is streamed in real time to the cloud dashboard, allowing remote access via web browsers and mobile phones.

Yes. You can configure high and low thresholds for each parameter. When an excursion occurs, instant alerts are broadcast via SMS, WhatsApp, email, and the local alarm buzzer.

Yes. An onboard rechargeable lithium battery backup sustains 48 to 120 hours of continuous logging. Data is stored safely to the 8–32GB SD card and synchronized to the cloud once power is restored.

Yes. AIOTHUB provides NABL-traceable calibration certificates for temperature, relative humidity, and barometric pressure, ensuring compliance during third-party quality audits.

The AIOTHUB Environmental Data Logger starts from ₹20,000 for standard Temp+RH+Barometer configurations, with pricing ranging up to ₹40,000 for multi-sensor setups including NDIR CO₂, VOCs, and PM2.5 laser sensors.

Get a Quote for Your Environmental Monitoring Deployment

Tell us about your application and we'll configure, calibrate, and ship an environmental logger ready to run — pan-India, free shipping, 1-year warranty.